UL 248-11:2005 pdf download – Low-Voltage Fuses一Part 11: Plug Fuses
UL 248-11:2005 pdf download – Low-Voltage Fuses一Part 11: Plug Fuses. NOTE – This Parr is intended w be read together with the Standard for Low-Voltage Fuses — Part 1: General Requirements. hereafter referred to as Parr). The numbering of the...
UL 248-9:2005 pdf download – Low-Voltage Fuses一Part 9: Class K Fuses
UL 248-9:2005 pdf download – Low-Voltage Fuses一Part 9: Class K Fuses. 1 General NOTE – This Part is intended to be read together with the Standard for Low-Voltage Fuses — Part I: General Requirements. hereafter referred to as Parr 1....
UL 248-5:2005 pdf download – Low-Voltage Fuses一Part 5: Class G Fuses
UL 248-5:2005 pdf download – Low-Voltage Fuses一Part 5: Class G Fuses. NOTE This Pan is 4,iended to be read together aWl, the Standard Jr Low Voltage Fuses – Part 1: General Requenients, hereafter relarred to as Pant. Th nmjsevlng of...
UL 248-3:2005 pdf download – L ow-Voltage Fuses – Part 3: Class CA and CB Fuses
UL 248-3:2005 pdf download – L ow-Voltage Fuses – Part 3: Class CA and CB Fuses. This is the common UL GSA, and ANCE Standard for Low- Voltage Fuses — Part 3: Class CA and CB Fuses. This is the...
UL 201:2005 pdf download – Garage Equipment
UL 201:2005 pdf download – Garage Equipment. 47.5 Equipment intended tor connection to an ac mains supply shall be tested over a tolerance of +6 percent and -10 percent, unless: a) The rated voltage is 230 V single phase or...
UL 147:2005 pdf download – Hand-Held Torches For Fuel Gases
UL 147:2005 pdf download – Hand-Held Torches For Fuel Gases. 8.4 Water o other liquid of comparable or lighter viscosity may be used for producing the required pressure in a hydrostatic-pressure strength lest. 9 Filling Procedure Test 9.1 The risk...
UL 331:2017 pdf download – Strainers for Flammable Fluids and Anhydrous Ammonia
UL 331:2017 pdf download – Strainers for Flammable Fluids and Anhydrous Ammonia. 8.5 A flat gasket employed with a bolted cover shall be cemented to the cover or body unless the construction is such that the gasket will be retained...
UL 96A:2007 pdf download – Installation Requirements for Lightning Protection Systems
UL 96A:2007 pdf download – Installation Requirements for Lightning Protection Systems. 9.3.3 Each down conductor located in a runway, driveway, school playground, cattle yard, public walk, or other similar location shall be protected from mechanical damage or displacement. A conductor...
UL 82:2008 pdf download – Electric Gardening Appliances
UL 82:2008 pdf download – Electric Gardening Appliances. C) The trimmer is marked In accordance with 56.4; and d) The tip speed, as determined by the average measurement of six trimmers, does not exceed 32.000 feet (9754 m) per minute...
UL 305:2017 pdf download – Panic Hardware
UL 305:2017 pdf download – Panic Hardware. 8 Elevated Ambient Exposure Test 8.1 A product that incorporates operating parts having a solidus point less than 1000°F (538°C) shall comply with 8.2. 8,2 Two complete samples of the panic hardware are...