IEC 60603-7-4:2010 pdf – Connectors for electronic equipment – Partie 7-4: Detail specification for 8-way, unshielded, free and fixed connectors,for data transmission with frequencies up to 250 MHz.
This pad of IEC 60603 covers 8-way, unshielded, free and fixed connectors, references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-
7. and specifies electrical transmission requirements for frequencies up to 250 MHz. These connectors are typically used as category 6 connectors in class E cabling systems specified in
ISOIIEC 11801.
These connectors are intermateable and interoperable with other IEC 60603.1 series connectors as defined in Clause 2 of IEC 60603-7.
These connectors are backward compatible with other IEC 60603-7 series connectors.
NOTE Tr.nmision performance cal.gonei: in this PEC stan4ard, ttie term category. e*en uaed in rif.renc. to tranmlse4on performance, refers to those categories de1ried by ISO/IEC 11801
1.2 Normative references
The following referenced documents are indispensable for the application of this document, For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
IEC 60512-1-100, Connectors for electronic equipment — Pert 1-100: General — Appl,cable publications
IEC 60512-2-1, Connectors for electronic equipment — Tests and measurements — Pan 2-1:
Electrical continuity and contact resistance tests — Test 2a: Contact resistance — Millivolt level method
IEC 60512.27.100, Connectors for electronic equipment — Tests and measurements — Part
27-100: Signal integrity tests up to 500 MHz on IEC 60603-7 series connectors — Tests 27a to
27g
IEC 60603-7:2008, Connectors for electronic equipment — Part 7: Detail specification for 8- way, unshielded, free and fixed connectors
IEC 61156 (all parts): Multi-core and symmetrical pair/quad cables for digital communications
IEC 62153-4-12:2009, Metallic communication cable test methods — Part 4-12:
Electromagnetic compatibility (EMC) — Coupling attenuation or screening attenuation of connecting hardware — Absorbing clamp method
64.3 Current-temperature derating See 6.4.3 of IEC 60603-7.
6.4.4 Initial contact resistance — Interface only (separable fixed and free contact) See 6.4.4 of IEC 60603-7.
6.4.5 Input to output d.c. r.slstanc. See 6.4.5 of IEC 60603-7.
6.4.6 Input to output d.c. resistance unbalance See 6.4.6 of PEC 60603-7,
6.4.7 Initial Insulation resistance See 64.7 of IEC 60603-7,
6.4.8 Transfer impedance See 6.4.8 of IEC 60603-7.
6.4.9 Coupling attenuation
Conditions:
IEC 62 153-4-12
Mated connectors
All pairs: 35 dB from 30 MHZ to 100 MHz
75 — 20109(1) dB from 100 MHz to 1 000 MHz
NOTE CouplIng allenuabon is assumed to be fultilled when transverse conversIon loss arid transverse conversion tranf.r lois are met from 1 MHz to 250 MHz
6.5 Transmission characteristics
6.5.1 General
Compliance to this standard, in respect to transmission characteristics, is determined according to specific test methods described in test group EP, see Table 1. The interoperability of connectors compliant to this standard shall be demonstrated by testing the fixed connectors with the full range of free connectors according to EC 60512.27.1002.
All transmission performance requirements apply between the reference planes specified in
IEC 60512-27-100.
NOTE in the toiIowrng sub clauses t the frequency espressed In MHZ.
6.5.2 Insertion loss
Conditions:
IEC 60512. test 27a
7.5 PreconditioningSee 7.5 of IEC 60603-7.
7.6Wiring and mounting of specimens7.6.1 wiring
Wiring of these connectors shall take into account the wire and cable diameter of the cablesdefined in the IEC 61156 series as applicable by manufacturer’s specification.
7.6.2 Mounting
See 7.6.2 of lEC 60603-7.
7.7Test schedules
The test parameters required shall not be less than those listed in Clause 6.
7.7.1 Basic (minimum) test schedule
Not applicable.
7.7.2 Full test schedule7.7.2.1General
ln addition to the test schedule of lEC 60603-7,one further group of two sets of matedconnectors is required for group EP.The free connectors for group EP shall additionally meetthe requirements of the lEc60512-27-100.
7.7.2.2 Test group P preliminary
All the test group specimens shall be subjected to the preliminary group P of lEC 60603-7.7.7.2.3Test group AP
See 7.7.2.3 of lEC 60603-7.7.7.2.4 Test group BPSee 7.7.2.4 of lEC 60603-7.7.7.2.5 Test group cPSee 7.7.2.5 of lEC 60603-7.7.7.2.6Test group DPSee 7.7.2.6 of IEC 60603-7.