IEC 60603-7-5:2010 pdf – Connectors for electronic equipment – Part 7-5: Detail specification for 8-way,shielded, free and fixed connectors,for data transmission with frequencies up to 250 MHz.
This part or IEC 60603 covers 8-way. shielded, free and fixed connectors and references dimensional, mechanical, electrical and environmental characteristics and tests in IEC 60603-7 and IEC 60603-7-1. and specifies electrical transmission requirements for frequencies up to 250 MHz. These connectors are typically used as category 6 connectors in class E cabling systems specified in ISO/IEC 11801
These connectors are intermateabTe and interoperable with other IEC 60603-7 series
connectors as defined in Clause 2 of IEC 60603-7.
These connectors are backward compatible with other lEG 60603.7 series connectors.
NOTE Transmiasion p.rformsnc. cat.gori. in this IEC standard, th term category wq.n us.d in relerenc. to tr5n5mission performance, refers to those categories defined by 1SO(IEC 11801
1.2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies
IEC 60512-1-100, Connectors for electronic equipment — Part 1-100: General — Applicable publications
IEC 60512-2-1, Connectors for electronic equipment — Tests and measurements — Part 2.1:
Electrical continuity and contact resistance tests — Test 2a: Contact resistance — Millivolt level method
IEC 60512-27-100, Connectors for electronic equipment – Tests and measurements — Pert
27-100: Signal integrity tests up to 500 MHz on IEC 60603-7 series connectors — Tests 278 to
27g
IEC 60603-7:2008, Connectors for electronic equipment — Part 7: Detail specification for 8- way, unshielded, free and fixed connectors
IEC 60603-7-1:2009. Connectors for electronic equipment — Part 7-1: Detail specification for 8-way, shielded, free and fixed connectors
IEC 61156 (all parts): Multi-core and symmetrical pair/quad cables for digital communications
fixed connectors with the full range of free connectors according to IEC 60512271002 Transmission performance backward compatibility shall be demonstrated by testing the fixed connectors with the full range of free connectors described in IEC 60512-27-100
All transmission performance requirements apply between the reference planes specified in
IEC 60512-27-100.
NOTE In the tolIemri subclauses V the frequency explessed In MHz.
65.2 InsertIon loss
Conditions:
IEC 60512. test 27a
Mated connectors
All pairs:  0,02t7 dB from 1 MHz to 250 MHz
Whenever the equation results in a value less than 0,1 dB, the requirement shall revert to 0,1 dB.
6.5.3 Return loss
Conditions:
IEC 60512. test 27b
Mated connectors
All pairs:  64-2Olog (I) dB from 1 MHz to 250 MHz.
Whenever the equation results in a value greater than 30 dB, the requirement shall
revert to 30 dB.
6.5.4 PropagatIon delay All pairs:  2.5 ns
Propagation delay test does not need to be performed, since it Is assumed that connectors comply by design.
6.5.5 Delay skew
All pair combinations:  1,25 ns
NOTE This cltaractefist)c is calculated Irom the individual propagahon delay measurements and, as with propagation de4ay (6.5.4), Ills assum.d that conneclors comply by d.sign
6.5.6 NEXT
Conditions:
IEC 60512, test 27c
Mated connectors
All pair combinations:  94.20109 (1’) dB from 1 MHz to 250 MHz.
Whenever the equation results in a value greater than 75 dB. the requirement shall
revert to 75 dB.
6.5.7 Power sum NEXT (for information only)
Conditions.
7Tests and test schedule7.1General
See 7.1 of IEC 60603-7.
7.2Arrangement for contact resistance test
For useful information regarding contact resistance tests see 7.2 of IEC 60603-7.7.3Arrangement for vibration test
For useful information regarding the principle of vibration tests see 7.3 of lEC 60603-7.7.4Test procedures and measuring methods
see 7.4 of IEC 60603-7.
7.5 Preconditioningsee 7.5 of IEC 60603-7.
7.6wiring and mounting of specimens7.6.1 wiring
Wiring of these connectors shall take into account the wire and cable diameter of the cablesdefined in the IEC 61156 series as applicable by manufacturer’s specification.
7.6.2 Mounting
See 7.6.2 of lEC 60603-7.7.7Test schedules
The test parameters required shall not be less than those listed in Clause 6.7.7.1 Basic (minimum) test schedule
Not applicable.
7.7.2 Full test schedule7.7.2.1 General
ln addition to the test schedules of lEC 60603-7 and lEC 60603-7-1, one further group of twosets of mated connectors is required for group EP. The free connectors for group EP shalladditionally meet the requirements of the lEc 60512-27-100.
7.7.2.2Test group P preliminary
All the test group specimens shall be subjected to the preliminary groups P of lEC 60603-7and lEC 60603-7-1.
7.7.2.3Test group AP
See 7.7.2.3 of lEC 60603-7 and of lEC 60603-7-1.